| Sign In | Join Free | My benadorassociates.com | 
 | 
Place of Origin : China
Brand Name : SOROTEC
Certification : CE,ROHS,ISO9000
MOQ : USD10000
Packaging Details : Standard Exported Cartons and Pallets
Delivery Time : Within 15-30days after receiving your 30% TT deposit
Payment Terms : 30% TT in advance, the balance before shipping
Supply Ability : 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS
Pure sine wave output coil in EPS Emergency Power Supply applied to banks
Features
	Applications
	Our EPS YJS series is extensively applied to banks, hospitals, hotels, markets, schools, bus or rail stations, sea or air ports, exhibition buildings, sport buildings, tunnels, etc.
Technical Specification of Lighting Power EPS (Emergency Power Supply) EPS YJS series
| Model | YJS series 2.2-500KW | |
| YJS 2.2-22KW | YJS 25-500KW | |
| Input | ||
| Voltage | 380VAC ± 25% | |
| Phase | Three phases + four wires + PE | |
| Frequency | 50HZ ± 5% | |
| Output | ||
| Capacity | 2.2KW - 500KW | |
| Voltage | 380VAC ± 3% | |
| Wave form | Sine wave (THD ≤ 3%) | |
| Frequency | 50HZ ± 0.5% | |
| Overload | ≥ 120% 30 s , ≥ 150% 5 s | |
| Battery | ||
| Type | VRLA (valve regulated lead acid), sealed, and maintain-free. | |
| Nominal voltage | 216VDC | 324VDC | 
| Charge time | < 24 hours | |
| Backup time | 90 minutes (Chinese standard, and it's adjustable.) | |
| Transfer time | <5 s (≤ 0.25s, ≤ 0.25ms or 0ms is optional) | |
| Protection | Overload, short-circuit, low voltage and lacking phase. | |
| Display | LED or LCD, or both LED and LCD | |
| Efficiency | DC mode ≥ 92%, AC mode ≥ 98% | |
| Working condition | ||
| Noisy (1 m distance) | AC mode 0 dB, DC mode ≤50dB (≥75KW, ≤65dB) | |
| Humidity | 0-90% non condensing | |
| Temperature | -20℃ - 40℃ | |
| Height of sea level | > 2000m | |
| Adaptive load | Suitable to both the inductive load and inductance capacitance load, or mixed load. | |
| Open doorr and coil in method | Single open for front door, double open for back door, coil in and out in bottom (standard or customized). | |
|   | 
| Pure sine wave output coil in EPS Emergency Power Supply LED applied to banks Images | 
 Lighting RS232 or RS485 0.5KW, 1KW 36VDC EPS Emergency Power Supply YJ series
                                                                                    
                        
                        
                        
                                                            Lighting RS232 or RS485 0.5KW, 1KW 36VDC EPS Emergency Power Supply YJ series
                                                    
                        
                     380V 50Hz EPS Emergency Power Supply for fire fighting YJS Series 2.2 - 500KW
                                                                                    
                        
                        
                        
                                                            380V 50Hz EPS Emergency Power Supply for fire fighting YJS Series 2.2 - 500KW
                                                    
                        
                     Industrial UPS (DC Bus)
                                                                                    
                        
                        
                        
                                                            Industrial UPS (DC Bus)
                                                    
                        
                     Single phase 220V 90KW / 100KW / 200KW EPS Emergency Power Supply with CPU
                                                                                    
                        
                        
                        
                                                            Single phase 220V 90KW / 100KW / 200KW EPS Emergency Power Supply with CPU
                                                    
                        
                     324V 3phase EPS Emergency Power Supply Sinewave YJS Series
                                                                                    
                        
                        
                        
                                                            324V 3phase EPS Emergency Power Supply Sinewave YJS Series
                                                    
                        
                     1.5KW / 2KW / 3KW single phase 96VDC EPS Emergency Power Supply with LCD
                                                                                    
                        
                        
                        
                                                            1.5KW / 2KW / 3KW single phase 96VDC EPS Emergency Power Supply with LCD
                                                    
                        
                     6KW / 7KW / 8KW / 9KW / 10KW EPS Emergency Power Supply synchronized with the
                                                                                    
                        
                        
                        
                                                            6KW / 7KW / 8KW / 9KW / 10KW EPS Emergency Power Supply synchronized with the
                                                    
                        
                     RS232 YJ series THD EPS Emergency Power Supply with CPU control for over
                                                                                    
                        
                        
                        
                                                            RS232 YJ series THD EPS Emergency Power Supply with CPU control for over
                                                    
                        
                     AC - DC VRLA non continuous EPS Emergency Power Supply with LCD display under
                                                                                    
                        
                        
                        
                                                            AC - DC VRLA non continuous EPS Emergency Power Supply with LCD display under
                                                    
                        
                     3 phases + 4 wires + PE IPM module EPS Emergency Power Supply for centralized
                                                                                    
                        
                        
                        
                                                            3 phases + 4 wires + PE IPM module EPS Emergency Power Supply for centralized